New Hydration Water Filling Station

March 2, 2023

Larry's Plumbing recently installed a hydration water filling station for one of our clients.


Hydration is essential for good health. Introducing Elkay's EZH2OTM bottle filling station
 
Ideal for education, healthcare facilities, fitness clubs, and hospitality


EZH2O bottle filling station provides convenient hydration, reduces our dependency on plastic water bottles, provides a rapid fill water to quench thirst and help minimize disposable plastic bottle waste in the environment.


QUICK, CLEAN + GREEN

–The EZH2O bottle filling station fill rate* is 1.1-1.5 gpm; 3 times faster than a traditional drinking fountain
–One-handed operation allows for a quick fill between activities
–The electronic sensor provides touchless, sanitary operation; just place and fill
–Available as Filterless or with the WaterSentry® Plus 3000 gallon filter is included (NSF 42 & 53 certified for particulate, chlorine, taste & odor and lead reduction)
–Integrated Silver Agion Anti-microbial protects against mold and mildew growth
–Innovative Green TickerTM counts the quantity of bottles saved from land fills


* Fill rate is 1.1 gpm for refrigerated units and 1.5 gpm for non-refrigerated units

October 2, 2026
Arrived on site to replace tankless water heater under manufacture warranty. Turned off unit, water and gas. Disconnected service valves and supply lines. Cut out recirculating and condensation lines. Cut out section of exhaust pipe. Remove defective tankless water heater. Installed new tankless water heater and secured to wall. Installed new section of exhaust pipe with fittings and secured. Reconnect and re-piped all supplies then braced. Turned on unit and bled system. Contacted tech support to properly set up commercial tankless configuration per manufacture recommendations. Set temperature at 140°.
September 21, 2026
Residential Instalation of Bradford White Water unit. Arrived on site, disconnected and drained existing 50 gallon tank, removed and disposed of unit. Installed new Bradford White 75 gallon, re-piped gas lien with full part valve. Installed new 1" hot/ cold water lines.
September 15, 2026
Both 3" valves to tank were already shut off. Began cutting on vertical line above 3'' x 3'' x 1" tee and also cut by in between the coupling and the flange. Removed both 3 x 3 x 1 tees and the 3" 90 degree. Installed 2 3 x 3 x 1 tees with 1 x 3/4 x 1/2 bushing and connected both lines along with 2-3" coupling and a 3" 90 degree. Need to wait 24 hours to dry. Cleaned work area.
More Posts